Multi column solutions for tailored for adsorbent

Meet our revolutionizing multi column solutions. Tailored for adsorbent users and developers. Ready to fast and accurately test your adsorbent performance.

  • Fast adsorbent screening and reduced time to market through parallelization
  • Fast selection of optimized process conditions by offering a wide window of test conditions and operational parameters
  • Unrivalled reliable results by testing multiple samples simultaneously under identical test conditions
  • Reduced experimental costs per sample due to small sample volume
  • Ideal hydrodynamics by narrow reactors and single string loading
  • Select the best adsorbent for your desired separation by adsorbent preparation, testing and matching

Reliable results

Our parallel testing systems provide accuracy by the total flow of a massflow controller, while the precision is the equal distribution between the columns to achieve a true parallel system. To ensure an equal pressure drop and to achieve a similar flow rate to each column channel, we make use of our proprietary high precision microfluidic flow distributor chips. Each microfluidic chip is tested in-house for a guaranteed flow distribution, with the precision between the channels guaranteed < 0.5%RSD. Pressure control within our systems is typically +/- 0.5% and with the Pressure Control System (RPC) 0.1%.

Identical test conditions

Unparalleled accuracy and repeatability

The key to success in small-scale parallel column systems is to be able to test adsorbents at exactly the same process conditions over multiple experiments, and to translate these into commercial values. The two crucial ingredients for succeeding with that approach are accuracy and repeatability.

Ideal Hydrodynamics

Control over hydrodynamics in the gas phase can be achieved by loading granular adsorbents as a single string in tubes.

 

  • Choosing a suitable space velocity allows us to test the adsorbent, loaded as a single string, on its performance free of hydrodynamic interference. The data that we gather is valuable information for optimizing for your process modelling.
  • To study the hydrodynamic effects of the adsorbent bed packing, we are able to vary the bed length by loading different amounts of adsorbents and/or different sizes.

Flowrence® products specifications

Reactor Section

Easy and quick reactor exchange system. Possibility to use quartz reactors at high pressure.

1 block of 4 reactors

HT = High Temperature max. 800°C nominal, limited to 925°C (<0.5°C reactor to reactor deviation)

4 blocks of 4 reactors

HT  or MT = Medium Temperature max. 525°C (<0.5°C block-to-block deviation)

16 reactors with iRTC

individual Reactor Temperature Control
max. 550°C (<0.5°C reactor-to-reactor)

4 reactors with iRTC

individual Reactor Temperature Control
max. 550°C (<0.5°C reactor-to-reactor)

Temperature Ranges (°C)

100 – 800°C
up 925°C (Option)

50 – 525°C
100 – 800°C
up 925°C (Option)

50 – 550°C

50 – 550°C

Reactor Types

L= Length
OD= Outer Diameter
ID= Inner Diameter
SS= Stainless Steel (< 550⁰C)
Qz= Quartz (< 925⁰C)

L 300 mm 561 mm
OD 3 mm 6 mm
ID SS 2 / 2.6 mm 2 / 3 / 4 / 5 mm
ID Qz 2 mm 2 / 4 mm
300 mm 561 mm 561 mm
3 mm 3 mm 6 mm
2 / 2.6 mm 2 / 2.6 mm 2 / 3 / 4 / 5 mm
2 mm 2 mm 2 / 4 mm
561 mm
3 mm
2 / 2.6 mm
2 mm
561 mm
3 mm
2 / 2.6 mm
2 mm

Maximum Catalyst Bed Length

(isothermal zone tolerance ± 1°C)
Note: isothermal length is dependent on the temperature range

300 / 3 HT 561 / 6 HT
>120 mm @ 450°C >200 mm @ 500°C
>90 mm @ 800°C >150 mm @ 800°C
>140 mm @ 925°C
300 / 3 HT 561 / 3 MT 561 / 6 HT
>120 mm @ 450°C >310 mm @ 450°C >200 mm @ 500°C
>90 mm @ 800°C >150 mm @ 800°C
>140 mm @ 925°C
561 / 3 MT iRTC
250°C ±0.5°C 41cm (4reactors)
350°C±0.5°C 38cm (4reactors)
550°C±0.5°C 28cm (4reactors)
3 reactors at 550°C, 1 reactor 350°C:
550°C=27cm 350°C=41cm ±0.5°C
561 / 3 MT iRTC
250°C ±0.5°C 41cm (4reactors)
350°C±0.5°C 38cm (4reactors)
550°C±0.5°C 28cm (4reactors)
3 reactors at 550°C, 1 reactor 350°C:
550°C=27cm 350°C=41cm ±0.5°C

Catalyst Volume (mL)

(isothermal zone)

0.2 - 0.6 mL 0.4 - 2.0 mL
0.2 - 0.6 mL 0.4 - 1.0 mL 0.4 - 2.0 mL
0.4 - 1.0 mL
0.4 - 1.0 mL

Pressure Ranges (barg)

2 – 80 barg
0.5 – 180 barg (option)

2 – 100 barg
0.5 – 180 barg

2 – 80 barg
0.5 – 180 barg

2 – 20 barg
2 – 50 barg (option)

Reactor Pressure Control

Advanced control RSD ±0.1 barg at reference conditions (gas phase only and 20 barg). For trickle flow Advanced control RSD ±0.5barg.

Standard (±0.5 barg)
Advanced (±0.1 barg) (option)

Standard (±0.5 barg)
Advanced (±0.1 barg) (option)

Advanced (±0.1 barg)

Advanced (±0.1 barg)

Gas Feed Lines

(#Gas Feeds)

Up to 6 + Diluent gas

He, Ar, N2, H2, CH4, CO2, C2H4, C2H6, O2/Inert (≤5%), CO, Other gases

Up to 7 + Diluent gas

He, Ar, N2, H2, CH4, CO2, C2H4, C2H6, O2/Inert (≤5%), CO, Other gases

Up to 7 + Diluent gas

He, Ar, N2, H2, CH4, CO2, C2H4, C2H6, O2/Inert (≤5%), CO, Other gases

Up to 6 + Diluent gas

He, Ar, N2, H2, CH4, CO2, C2H4, C2H6, O2/Inert (≤5%), CO, Other gases

Online Analysis

Full integration GC, MS , GC/MS with data visualisation (option)

Full integration GC, MS , GC/MS with data visualisation

Full integration GC, MS , GC/MS with data visualisation

Full integration GC, MS , GC/MS with data visualisation

Liquid Feed

 Split feeding 8 + 8 reators (option)

Pump-Coriolis dosing system
(ambient, cooled)

Pump-Coriolis dosing system
(ambient, cooled, heated 80°C)

Pump-Coriolis dosing system
(ambient, cooled, heated 80°C)

Pump-Coriolis dosing system
(ambient, cooled, heated 80°C)

Liquid Distribution

Microfluidic Distribution
(4-channel glass-chip)

Microfluidics Distribution
(4x4-channel glass-chip)
(16-channel glass-chip)
Active Liquid Distribution (option)
(with automatic isolation valves)

Active Liquid Distribution
(with automatic isolation valves)

Microfluidic Distribution
(4-channel glass-chip)

Liquid Sampling

(G/L Separation)

Parallel liquid sampling (4 x 20ml vials) with sequential on-line gas phase sampling (option)

Automated liquid sampling (4 rows x 16 vials x 8ml) with sequential on-line gas phase sampling (option)

Automated liquid sampling (4 rows x 16 vials x 8ml) with sequential on-line gas phase sampling (option)

Parallel liquid sampling (4 x 20ml vials) with sequential on-line gas phase sampling (option)

Reactors Effluent Handling

(Off-line Analysis Connection)

Full heated circuit up to 180°C with sequential on-line full gas phase sampling (option)

Full heated circuit up to 200°C with sequential on-line full gas phase sampling

Full heated circuit up to 200°C with sequential on-line full gas phase sampling

Full heated circuit up to 200°C with sequential on-line full gas phase sampling

Offline Analysis

Integrated Workflow: SimDist, total S/N, liquid density, balance, label printer, barcode (option)

Integrated Workflow: SimDist, total S/N, liquid density, balance, label printer, barcode

Integrated Workflow: SimDist, total S/N, liquid density, balance, label printer, barcode

Integrated Workflow: SimDist, total S/N, liquid density, balance, label printer, barcode

Waste Handling

Ambient temperature
Heated wax trapping (option)

Ambient temperature / Cooled containers / Heated compartment (wax trapping, heavies)

Ambient temperature / Cooled containers / Heated compartment (wax trapping, heavies)

Ambient temperature / Cooled containers / Heated compartment (wax trapping, heavies)

Safety

Gas sensors and control box (CO, LEL, VOC)

Gas sensors and control box (CO, LEL, VOC)

Gas sensors and control box (CO, LEL, VOC)

Gas sensors and control box (CO, LEL, VOC)

Flowrence® Software

Flowrence® recipe builder, control & database builder

Flowrence® recipe builder, control & database builder

Flowrence® recipe builder, control & database builder

Flowrence® recipe builder, control & database builder

Microfluidics modular gas distribution

Unrivalled accuracy in gas distribution with patented glass-chips for 4 and 16 reactors, with a guaranteed flow distribution of 0.5% RSD. Quick exchange of glass-chips for different operating conditions. Flexibility to cover a wide range of applications.

TinyPressure glass-chip holder with integrated pressure measurement

Compact modular design for gas and liquid distribution. No high-temperature pressure sensors required. Quick exchange of the microfluidic glass-chips, without the need for time-consuming leak testing.

Tube-in-tube reactor technology with effluent dilution

Unique tube-in-tube design with easy and rapid exchange of the reactor tubes (within minutes!). No need for any connections. Use of inert diluent gas (outside of reactor) to maintain the pressure prevents dead volumes and back flow. Possibility to use quartz reactors at high pressure applications.

Automated liquid sampling system

Programmable, fully automated liquid product sampling robot for 24/7 hands-off operation. Robot equipped with a compact manifold aiming at depressurizing the effluent immediately after each reactor to atmospheric pressure. Eliminates the use of high pressure valves.

Reactor Pressure Control (RPC)

The most accurate and stable pressure regulator for a 16-parallel reactors with just ±0.1bar RSD. The RPC uses microfluidics technology to regulate the pressure of each reactor, maintaining equal distribution of the inlet flow over the 16 reactors.

Auto-calibrating liquid feed distribution, measurement, and control

Distribution of difficult feedstocks e.g., VGO, HVGO, DAO. Liquid distribution 0.2% RSD, making it the most accurate liquid distribution device on the market. Option to selectively isolate each reactor.

Single-Pellet-String-Reactors (SPSR)

No dead-zones, no bed packing & distribution effects. The catalyst packing is straightforward and does not require special procedures. A single string of catalyst particles is loaded in the reactors avoiding maldistribution, eliminating channeling and incomplete wetting.

EasyLoad®

Unique reactor closing system with no connections. Rapid reactor replacement minimizing delays, improving uptime and reliability. Stable evaporation by liquid injection into reactor.

Contact us

We are here to help you

 

 

 

 

 

 

 

 

Avantium Headquarters

+31 (0)20 586 8080

Zekeringstraat 29
1014 BV Amsterdam
The Netherlands

Contact us