Watermark short

Software Solutions

Fully integrated software purposely designed for our high-throughput systems. Seamlessly integration with all IT infrastructures and catalyst R&D workflow

Fully automated and unattended 24/7 operation

  • Integration with other software platforms e.g., i-historian etc.
  • Automated liquid sampling using barcode labeling
  • Tracking catalyst samples and liquid feed properties
  • Integration of analytical data & feedback control
  • Calculation of key performance data like conversion and selectivity
  • Stored values can be used to monitor trends in built-in plots
  • Alarm management for all relevant process values

Automated operation with predefined recipes

A recipe is a compilation of conditions steps containing set points, ramp rates and reactor sampling, waiting times between GC analyses, etc. In a recipe, an unlimited number of steps with various process conditions can be added. This unique feature allows unattended operation of the unit during a test run.

Every second, all measured values and set points are stored in a SQL database

All online and offline results are automatically imported into the Flowrence® Database and available on a real-time basis. Additionally, when a GC chromatogram is reprocessed (e.g. to assign a different retention time or response factor), the new results will be automatically updated into the database.

The control software will be directly connected to a Microsoft SQL server database where all relevant information of the experiment is automatically stored. This information is stored at a very high detail level of 1 sample per second to allow very accurate trending. This enables real-time follow up of the experiment and determine whether any adjustments need to be made to the process parameters.

Flowrence® Products

Flowrence® XD

4 Reactors

Avantium’s most flexible and easy to use system with a broad number of proven applications. Designed for early-stage catalyst R&D.

Flowrence® XR

16 Reactors

Our most accurate system with a broad operating window. Designed for fast catalyst screening with outstanding repeatability and reproducibility.

Flowrence® XP

16 Reactors

Our most advanced system combining all technology of the Flowrence® XR with independent control per reactor for kinetic studies and process design.

Flowrence® XC

4 Reactors

This system was purposely designed for benchmarking of commercial catalysts.

Talk to an expert

Get in contact with our Business development team.Driven by a passion for creating a cleaner chemical sector, Avantium R&D Solutions is always open to solving any problems, no matter how big or small the ask.

+31 (0)20 5868080 or send us an email [email protected]